For our international customers, please be advised that orders cannot be placed through our website by customers in countries with International Distributor representation.
Leucine Aminopeptidase - Assay
Leucine Aminopeptidase Assay
- 0.025 M Manganese chloride
- 0.125 M Magnesium chloride
- 0.5 M Tris⋅HCl buffer, pH 8.5
- 0.0625 M L-Leucine, pH 8.5. Note: The extinction coefficient of L-leucinamide should be checked upon each use by the technique outlined in the procedure.
Prior to assay, the enzyme must be activated for two hours at 37°C in the following:
0.025 M Manganese Chloride 0.1 ml 0.5 M Tris⋅HCl buffer 0.1 ml Enzyme * Reagent grade water q.s. to 2.3 ml
* The volume of the sample activated may vary, depending upon the material to be assayed; however, no more than 0.4 mg of the purified product should be added to the activation mixture.
Determination of extinction coefficient
Prepare cuvettes as follows:
Control Test 0.0625 M L-leucine 2.0 ml ----- 0.125 M L-leucinamide ----- 1.0 ml 0.5 M Tris⋅HCl pH 8.0 0.1 ml 0.1 ml 0.125 M Magnesium chloride 0.1 ml 0.1 ml Reagent grade water 0.2 ml 1.2 ml
Using the control as an absorbance blank, determine A238 for test cuvette.
Calculate extinction coefficient (Em) as follows:
Determination of reaction rates:
Incubate test cuvettes in the spectrophotometer at 25°C for 4-5 minutes to achieve temperature equilibration and establish a blank rate, if any. Add 0.1 ml of enzyme activation mixture and record decrease in A238 from the linear portion of the curve. Some lag may occur during the initial period and should not be used in the calculation.